FD-5 Spectrodensitometer

 

 


FD-5 Spectrodensitometer: $3495.00

Accessories / Bundles / Upgrades / Add-ons
Target Mask for FD: $111.00
USB Cable for FD: $38.00
AC Adaptor (120V) for FD: $38.00
Soft Case for FD: $49.00
We Price Match! Call 1-877-265-6743 for details.

 

   
New Konica Minolta FD-5 Spectrodensitometer

2-in-1 lightweight, handheld spectrodensitometer that measures:

  • Color
  • Density
 

Notable Features

Color (L*a*b*)

  • Uniquely corresponds to Measurement Condition M1 of ISO 13655.
    • The world's first M1 type. Konica Minolta's original VFS (Virtual Fluorescence Standard) technology enables L*a*b* measurements corresponding to ISO 13655 Measurement Condition M1 (CIE Illuminant D50).
    • In addition, color measurements corresponding to ISO 13655 Measurement Conditions M0 (CIE Illuminant A) and M2 (illumination with UV-cut filter) can also be taken.
  • Industry's first automatic wavelength compensation function.
      
    • Wavelength compensation is performed automatically at the time of white calibration, so there is no extra work required. 
    • Wavelength compensation, which could previously be performed only through manufacturer servicing, can now be performed daily, drastically increasing the reliability of measurement values.
  • Enables color measurements that correspond more closely with visual evaluation.
    • When using conventional instruments to measure materials printed on substrates containing fluorescent whitening agents (FWA), large differences between the results of measurements and visual evaluation may occur. With the new FD-7/FD-5, measurement results correspond more closely to visual evaluation results, including the effects of any FWA in the paper.
 Density (CMYK)
  • World's lightest, as of 11/1/10
    • The main body weighs only about 350g, and even with the target mask attached it's only about 430g, lighter than any previous spectrodensitometer.
    • This reduces the load on the user's arm during work, improving efficiency when taking measurements over a long time.
  • Worry-free after-sales service
    • Worldwide service centers provide rapid support when needed.
    • A comprehensive service network is in place to ensure that your instrument is always in top shape.
  • Simple Operation
    • Measurements of density, dot area ratio, dot gain, color, and illumination are simple.
    • Operation is performed by just following the instructions in the LCD screen, so anyone can take measurements easily.
 

FD-5 Specifications:

  • Illumination/viewing system: 45°a: 0°(annular illumination)(Illumination for wavelengths under 400nm is unidirectional.) Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil 7, ASTM E 1164, and JIS Z 8722 Condition a for reflectance measurements.
  • Spectral separation device: Concave grating
  • Wavelength range: Spectral reflectance: 380 to 730 nm
  • Wavelength pitch: 10 nm
  • Half bandwidth: Approx. 10 nm
  • Measurement area: Ø3.5mm
  • Light source: LED
  • Measurement range: Density: 0.0D to 2.5D; Reflectance: 0 to 150%
  • Short-term repeatability: Density: 0.01D Colorimetric: Within E00 0.05 (When white plate is measured 30 times at 10-second intervals after white calibration has been performed)
  • Inter-instrument agreement: Within E00 0.3 (Average of 12 BCRA Series II color tiles compared to values measured with a master body under Konica Minolta standard conditions)
  • Measurement time: Approx. 1.4 s (single-point reflectance measurement)
  • Displayed values: Colorimetric values, color-difference values, density values, density-difference values, dot area ratio, dot gain, PASS/FAIL judgment
  • Measurement conditions: Corresponding to ISO 13655 Measurement Conditions M0 (CIE Illuminant A), M1 (CIE Illuminant D50), and M2 (illumination with UV-cut filter); User-defined illuminant
  • Illuminants: A, C, D50, ID50, D65, ID65, F2, F6, F7, F8, F9, F10, F11, F12, User-defined illuminant
  • Observers: 2° Standard Observer, 10° Standard Observer
  • Color spaces: L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ and color-difference in these color spaces
  • Color-difference equations: E*ab (CIE 1976), E*94 (CIE 1994), E00 (CIE 2000), E (Hunter), CMC (l:c)
  • Indexes: WI (ASTM E313-96); Tint (ASTM E313-96); ISO Brightness (ISO 2470-1); D65 Brightness (ISO 2470-2); Fluorescence index
  • Density: ISO Status T, ISO Status E, ISO Status A, ISO Status I; DIN16536
  • Storable data: Colorimetric target data: 30 data; Density target data: 30 data
  • Display language: English, French, German, Spanish, Japanese, Chinese (Simplified)
  • Scanning measurements: N/A
  • Interface: USB 2.0
  • Output data: Displayed values (Available when using PC software)
  • Power: Rechargeable internal lithium-ion battery (Number of measurements per charge: Approx. 2,000 when new); AC adapter; USB bus power
  • Dimensions (W × D × H): 70 × 165 × 83mm (Body only); 90 × 172 × 84mm (With target mask attached)
  • Weight: Approx. 350g (Body only); Approx. 430g (With target mask attached)
  • Operating temperature/humidity range: 10 to 35°C, 30 to 85% relative humidity with no condensation
  • Storage temperature/humidity range: 0 to 45°C, 0 to 85% relative humidity with no condensation