X-Rite i1Basic Pro2

 

 


i1Basic Pro 2 : $1380.00 $1275.00

Accessories / Bundles / Upgrades / Add-ons
Maxwell MeasureWatch Lifetime (1 inst) + Vogelsong COLORef CRM Target Bundle: $450.00 $300.00
We Price Match! Call 1-877-265-6743 for details.

 

   
The i1Basic Pro2 is a new level of color accuracy for the i1Pro family, delivering increased ease of use and an expanded professional level feature set, including supporting the latest developments in industry measurement standards.

i1Basic Pro2 Includes:

i1Pro 2 spectrophotometer (measurement device), calibration plate, ambient light measurement head, monitor holder, positioning target, scanning ruler, backup board, USB cable, i1Profiler v1.x software for monitors, PANTONE Color Manager software and soft-sided storage case.

*Note* i1Basic Pro (Generation 1) has been discontinued and no longer available as of May 1, 2012.

-

Why buy the Maxwell MeasureWatch + COLORef Bundle with your i1Pro2?

  • Early problem identification of your i1Pro2
  • Know exactly when your i1Pro2 instrument varies or needs servicing
  • Reduce or avoid yearly manufacturer calibrations and certifications of your i1Pro2
  • Aligns well with ISO instrument conformance programs
  • Protecting your i1Pro2 investment

MeasureWatch® is a Maxwell focused service specifically for tracking spectrophotometer instruments accuracy, performance and conformance to a standard or with other instruments. MeasureWatch performs Pass/Fail reporting, custom label printing, Trend Analysis and other strong reporting and analysis. MeasureWatch combined with a reference CRM is a perfect solution to measure, manage, track and analyze any spectrophotometer within your workflow or enterprise. Maxwell MeasureWatch plus COLORef® CRM (Color Reference Material) bundle is a perfect fit for your i1Pro2 and other critical instruments.

For more information about MeasureWatch and COLORef CRM - click here, or call a CHROMiX technical sales specialist at (206) 985-6837 Extension #1

 

Notable Features

The new i1Pro 2 spectrophotometer:

New illuminant design allows for 3 standard measurement conditions (ISO 13655 M0: Tungsten; ISO 13655 M1: D50; ISO 13655 M2: UV Cut) plus Optical Brightener Compensation (OBC) without changing filters or needing a second instrument.

Enhanced Optical Brightener Compensation allows for the most accurate profiling for todays enhanced range of substrates. Now users can predict what colors printed on optically brightened paper will look like under different light conditions using a single hand-held device.

Positioning Detection Sensor provides a more robust scanning experience even on special substrates and low-resolution printers. It allows for the measurement of smaller patch sizes (as low as 7mm) in manual mode and enables dual measurement workflows for OBC, M1 and M2.

New Status LED guides users through the measurement process and provides feedback on device status, improving the user experience.

New Design Ergonomics throughout allows for greater usability, flexibility, cleaning, protection, and storage of the precision i1Pro 2 device.

Better temperature stability and higher brightness levels improves emissive measurement, resulting in the best possible calibration and profiling of monitors and projectors.

All new diagnostics and self-correction features built-in wavelength calibration technology allows for self-diagnosis of optical grating in relation to sensor during white calibration (with automatic correction and notifications).

Maintaining and protecting the device (and investment) is easier than ever Self-cleanable aperture protection glass and calibration white tile cover provides additional built-in protection from dust and dirt.

i1Pro 2 is equipped with the X-Rite Graphic Arts Standard (XRGA) to make it quicker and easier for companies and professionals involved in digital production printing to adhere to ISO standards and have confidence that data sent or received from all links in the supply chain is reliable and repeatable.

 

Systems Supported for i1Profiler v1.5x

MacOS X 10.6.x, 10.7.x, 10.8x and 10.9x (with latest updates installed) 512MB RAM (2GB recommended) Intel® Core 2 Duo Processor Up to 500 MB of available disk space Powered USB Port Monitor resolution of 1024x768 pixels or higher minimum Dual display support requires either 2 video cards or a dual head video card that supports dual video LUTs being loaded DVD drive or high-speed internet connection required for software install, download and automatic software update User must have administrator rights to install and uninstall application

Microsoft® Windows® XP® 32 bit Microsoft® Windows® Vista® 32 or 64 bit Microsoft® Windows® 7® 32 or 64 bit Microsoft® Windows® 8® 32 or 64 bit Microsoft® Windows® 8.1® 32 or 64 bit All operating systems require latest updates and Service Packs installed 512MB RAM (2GB recommended) Intel® Core 2 Duo or AMD® Athlon® XP or better CPU Up to 500MB of available disk space (depending on components installed) Powered USB Port Monitor resolution of 1024x768 pixels or higher Latest drivers for video card installed Dual display support requires either 2 video cards or a dual head video card that supports dual video LUTs being loaded Network adaptor installed and driver loaded DVD drive or high-speed internet connection required for software install, download and automatic software update User must have administrator rights to install and uninstall application

i1Pro2 Hardware Specifications

SPECTRAL ENGINE i1® technology with built-in wavelengths check Spectral analyzer: Holographic diffraction grating with 128-pixel diode array Spectral Range: 380 - 730 nm Physical sampling interval: 3.5 nm Optical resolution: 10 nm Spectral reporting: 380 ... 730 nm in 10 nm steps Measurement Frequency in scanning mode: 200 measurements per second

OPTICS Measurement geometry: 45°/0° ring illumination optics, ISO 13655:2009 Measurement aperture: 4.5 mm (0.18) diameter (effective measurement aperture during scanning is depending on the patch size and measurement speed) Illumination Spot Size: 3.5 mm (0.14) Light source: Gas filled tungsten (illuminant type A) and UV LED

REFLECTANCE MEASUREMENT Data Format: Spectral Reflectance (dimensionless)

Measurement Conditions: UV included - ISO 13655:2009 measurement condition M0 D50 - ISO 13655:2009 measurement condition M1 UV excluded Filter - ISO 13655:2009 measurement condition M2 OBC: Optical Brightener Compensation (OBC) with i1Profiler software Calibration: Manual on external ceramic white reference Measurement Background: white, ISO 13655:2009; for measurements on backup board Maximum Media Thickness: 3 mm (0.12) on backup board Minimum Patch Size in Scanning Mode: 7 x 10 mm (0.28 x 0.39) (Width x Height) with sensor ruler 10 x 10 mm (0.39 x 0.39) (Width x Height) without sensor ruler Inter-instrument agreement: 0.4 E94* average, 1.0 E94* max. (deviation from X-Rite manufacturing standard at a temperature of 23ºC (73.4ºF) on 12 BCRA tiles (D50, 2º)) Short-term repeatability: 0.1 E94* on white (D50,2°, mean of 10 measurements every 3 seconds on white)

EMISSIVE MEASUREMENT Data format: Spectral radiance (mW/nm/m2 /sr); Luminance Y (cd/m2) Measurement range: 0.2 - 1200 cd/m2 on a typical LCD-Monitor Short-term repeatability: x,y: +/- 0.002 typical (5000°K, 80 cd/m2)

AMBIENT LIGHT MEASUREMENT Data Format: spectral irradiance (mW/nm/m2), illuminance (lux) Type: Cosine-corrected diffuse light measurement head

OPERATING CONDITIONS Temperature: 10°C (50°F)  35°C (95°F) Humidity: 0%  80% non-condensing

INTERFACE, DIMENSIONS AND WEIGHT Interface: USB 1.1 Power supply: Device powered by USB. No additional charger or battery required. USB 1.1 high power device.

Physical dimensions i1Pro2 device: Length 155 mm, width 66 mm, height 67 mm (6.1 x 2.6 x 2.6) i1 Ruler: Length 337 mm , width 102 mm (13.3 x 4.0) i1 Backup Board: 355 mm x 265 mm (14.0 x 10.4) folded or 355 mm x 400 mm (14.0 x 15.7) unfolded Weight i1Pro device: 245 g (8.6 oz)